National Loop Co. 17' (2.5' X 6') Direct Burial Vehicle Detection Loop with 100' Lead-In for 8.5' Wide Driveways - E-NL8.5-18-100

National Loop Co. 17' (2.5' X 6') Direct Burial Vehicle Detection Loop with 100' Lead-In for 8.5' Wide Driveways - E-NL8.5-18-100

Sensing traffic through the pavement itself, the National Loop Co. 17' Direct Burial Vehicle Detection Loop with a 100' lead-in stands in as the gate system's non-contact vehicle detection. Rather than cutting finished pavement, you set it on the base and let the new surface lock it in. At 17' of total loop length, the 2.5' x 6' layout fits 8.5' wide driveways, from older urban row homes and narrow driveways.
Part Number: E-NL8.5-18-100
$165.13 each $165.13 each
OR

Details

National Loop Co. 17' (2.5' X 6') Direct Burial Vehicle Detection Loop with 100' Lead-In for 8.5' Wide Driveways - E-NL8.5-18-100

Built for sites where saw-cutting is not an option, the National Loop Co. 17' Direct Burial Vehicle Detection Loop with 100' Lead-In is a preformed 18 AWG loop encased in liquid-tight conduit. Teamed with a loop detector, it gives the gate operator the presence detection it needs, so the gate reverses or holds open while a vehicle sits in the path. Installation is a lay-and-pave job: set the loop on the graded sub-base, run the lead-in to the detector, and let the paving crew cover it. Its 6' side spans the travel lane while the 2.5' side runs in the direction of traffic, leaving roughly 1' 3" of clearance on each edge, an arrangement well suited to older urban row homes, narrow driveways, and single-car gravel drives in rural areas.

Features:

  • Works wherever vehicles need detecting: automatic gates, parking barriers, overhead doors, traffic signals, arming devices, and vehicle counters
  • One continuous, non-spliced wire runs through the loop turns and lead-in, eliminating splice failures
  • Liquid-tight conduit stands between the wire and sharp stones, chemicals, ground movement, and harsh weather
  • Arrives fully assembled and ready to install under new asphalt, concrete, or gravel
  • Factory-set turn count means optimal read range without any on-site adjustment
  • More cost-effective than hand-wound loop installations

Specifications:

  • Loop type: Direct burial
  • Total loop length: 17'
  • Loop dimensions: 2.5' x 6'
  • Lead-in length: 100'
  • Wire gauge: 18 AWG
  • Wire material: Polypropylene-wrapped copper wire
  • Best-suited driveway width: 8.5'
  • Manufacturer: National Loop Company (NLC)
  • Made in America: Yes
Prefer to Call? (888) 378-1175

Questions about part number E-NL8.5-18-100?

Required Fields *

Name *

Email *

Phone

My Questions *

Loop Type Direct Burial
Lead-In Length 100'
Loop Length Size 2.5' X 6'
Total Loop Length 17'
SKU E-NL8.5-18-100
Product Type Direct Burial Preformed Loop
Made In America Tooltip
Learn More About BABA Certification
Yes
Ideal Application Arming Devices, Gate Operators, Overhead Doors, Parking Barrier Gates, Traffic Signals, Vehicle Counters
Material Polypropylene-Wrapped Copper Wires
Manufacturer National Loop Company - NLC
Specification Sheet Download PDF file